UDP
A Enable Enables/disables logging messages to a remote UDP logging/syslog server.
B IP Sets the IP address where the log messages should be sent via UDP. This parameter
accepts IPv4 addresses in the form aaa.bbb.ccc.ddd.
C Port Sets the port where the log messages should be sent via UDP. Disable UDP to
change. This parameter accepts values from 1 to 10000.
8.5.16 Diagnostics
This set of parameters report the state of various parts of the system upon boot (OK or fail). If
an error condition is observed, the unit should be re-booted and these parameters should be
examined. This information will be useful when contacting support.
DSPX Comm
This read only parameter reports communication failure with DSPX chip (OK/FAIL). Restart the
unit to refresh this value in case of failure.
Exciter Comm
This read only parameter reports communication failure with AIO exciter chip (OK/FAIL).
Restart the unit to refresh this value in case of failure.
Alarms DAC Comm
This read only parameter reports communication failure with Alarms DAC chip (OK/FAIL).
Restart the unit to refresh this value in case of failure.
Power DAC Comm
This read only parameter reports communication failure with Power DAC chip (OK/FAIL).
Restart the unit to refresh this value in case of failure.
8.5.17 About
Product ID
This read only parameter displays the product ID.
76