Parameters when Send via is set to BW Broadcast:
A From Sets the email address of the sender. The unit will send e-mails through this address.
This parameters accepts up to 64 characters of text.
B Recipient(s) Sets the recipients of the emails. Multiple addresses must be separated by
commas. This parameter accepts up to 99 characters of text.
C Max emails a day Sets the maximum number of emails allowed to be sent by the unit
in a single day. This is intended to stop spamming coming from intermittent fault condi-
tions. This parameter accepts values from 1 to 1000.
D Emails sent today Reports the number of emails sent today. This parameter accepts val-
ues from 0 to 100000.
8.5.12 HTTP
V2 Transmitters provide a graphical web based interface for ease of use and control. This
can be accessed by navigating to the IP address of the unit in any standard web browser.
After entering the login details for the unit, the user can then read and write all parameters
and also perform firmware upgrades. All parameters are saved and updated dynamically
as they are changed in the remote.
Enable
Enables/disables the web server.
Port
Sets the webserver TCP port. Disable HTTP to change. This parameter accepts values from 1
to 1024.
Remote Control Indication
Displays a message on the screen when the unit is being controlled remotely through the
web remote.
8.5.13 Telnet
For text based access via a local network or the internet, Telnet can be used to connect to
the unit.
74