Logging to a File in internal memory
If enabled, the system will keep logs of the last 31 days. These logs can be accessed through
the web remote.
An example section from a log file is shown below:
2013-04-22 11:40:06 DTLG > M: exciter_locked = 1
DTLG > M: peak_deviation = 75k
DTLG > M: fwd_power = 250
DTLG > M: rev_power = 3
DTLG > M: pa_voltage = 30.1
DTLG > M: aux_voltage = 15.1
DTLG > M: pa_temp = 30.0
DTLG > M: cpu_temp = 25.0
DTLG > M: tx_input_l = -38.997
DTLG > M: tx_input_r = -38.997
DTLG > M: agc1 = 0m
DTLG > M: agc2 = 0m
DTLG > M: agc3 = 0m
DTLG > M: agc4 = 0m
DTLG > M: lim1 = -5997m
DTLG > M: lim2 = -5997m
DTLG > M: lim3 = -5997m
DTLG > M: lim4 = -5997m
DTLG > M: tx_output_l = -14.000
DTLG > M: tx_output_r = -14.000
DTLG > M: tx_output_mpx = 0m
DTLG > P: transmitter.frequency = 98.00MHz
DTLG > Alarm status [3-0]: Off Off On Off