15
WIRE THE ENTRAPMENT PROTECTION DEVICES
WIRING
WIRE THE ENTRAPMENT PROTECTION
DEVICES
An entrapment protection device such as photoelectric sensors or an edge MUST be
wired to the operator and then configured for your application. Refer to page 18 -
page 21 for programming information.
PHOTOELECTRIC SENSORS
Entrapment protection devices are required.
Input for UL325 compliant entrapment protection devices such as photoelectric
sensors. Configure either CX, CY, or CZ (N.C.) contacts.
NOTE: If not used deactivate the contacts using the programming menu.
C1 “OPEN WHILE CLOSING” (N.C.) Contact
If the photoelectric sensor beam is blocked while the gate is closing, the gate will stop
and reverse to the fully open position.
C2 “CLOSE WHILE OPENING” (N.C.) Contact
If the photoelectric sensor beam is blocked while the gate is opening, the gate will
stop and reverse to the fully closed position.
C3 “PARTIAL STOP”(N.C.) Contact
If the photoelectric sensor beam is blocked while the gate is moving, the gate will
stop and automatically shuts (if this function has been selected).
C4 “STANDBY OBSTACLE” (N.C.) Contact
If the photoelectric sensor beam is blocked while the gate is moving, the gate will
stop and once the obstruction is removed the gate will resume moving in the same
direction.
DIR10 Photoelectric Sensors:
RX
TX

Table of Contents