26
MAINTENANCE CHART
MAINTENANCE
NOTES:
Severe or high cycle usage will require more frequent maintenance checks.
Limits may have to be reset after any major gate adjustments.
It is suggested that while at the site voltage readings be taken at the operator.
Using a digital voltmeter, verify that the incoming voltage to the operator it is
within ten percent of the operator’s rating.
MAINTENANCE CHART
Disconnect all power to the operator before servicing.
DESCRIPTION TASK CHECK AT LEAST ONCE EVERY
MONTH 6 MONTHS 3 YEARS
Entrapment Protection Devices Check and test for proper operation X
Warning Signs Make sure they are present X
Manual Disconnect Check and test for proper operation X
Gate Inspect for wear or damage and lubricate as needed X
Accessories Check all for proper operation X
Electrical Inspect all wire connections X
Chassis Mounting Bolts Check for tightness X
Operator Inspect for wear or damage X