Encoder Deceleration: this activates the opening and closing deceleration starting points.
M1 opening deceleration%: this adjusts the (M1) first motor’s deceleration starting point before the opening endpoint.
The deceleration starting point is calculated as a percentage (from 1% to 40% of a full gate run). See illustration on page 32.
N.B.: this function appears only if it is activated in the “decel. Enc” function in the ENCODER menu.
M1 closing deceleration%: this adjusts the (M1) first motor’s deceleration starting point before the closing endpoint.
The deceleration starting point is calculated as a percentage (from 1% to 40% of a full gate run). See illustration on page 32.
N.B.: this function appears only if it is activated in the “decel. Enc” function in the ENCODER menu.
M2 opening deceleration%: this adjusts the (M2) second motor’s deceleration starting point before the opening endpoint.
The deceleration starting point is calculated as a percentage (from 1% to 40% of a full gate run). See illustration on page 32.
N.B.: this function appears only if it is activated in the “decel. Enc” function in the ENCODER menu.
< Slow run Enc >
ON
Slow run Enc
< ON
>
Slow run Enc
< OFF
>
< M1 Slow.AP.% >
10
M1 Slow.AP.%
< 10
>
M1 Slow.AP.%
< 11
>