< M2 Slow.CH % >
10
M2 Slow.CH %
< 10
>
M2 Slow.CH %
< 11
>
M2 closing deceleration %: this adjusts the (M2) second motor’s deceleration starting point before the closing endpoint.
The deceleration starting point is calculated as a percentage (from 1% to 40% of a full gate run). See illustration on page 32.
N.B.: this function appears only if it is activated in the “decel. Enc” function in the ENCODER menu.
< M1 Appr.CH % >
5
M1 Appr.CH %
< 5
>
M1 Appr.CH %
< 6
>
< M2 Appr.CH % >
5
M2 Appr.CH %
< 5
>
M2 Appr.CH %
< 6
>
M1 Opening approach%: sets the point at which the gate begins adjusting deceleration before making contact with the closing
endpoint of the first motor (M1).The point the gate leaf enters its ajar closing phase is computed as a percentage (from 1% to 15%
of the full gate run). See illustration on page 32.
M2 % Ajar closing point: sets the ajar closing point percentage of the second M2 motor. The point the gate leaf enters its ajar closing
phase is computed as a percentage (from 1% to 15% of the full gate run). See illustration on page 32.