VIII. Servicing Notes
A. Power and Plug Requirements
Canon USA Inc. strongly suggests dedicated and properly grounded outlets be
provided.
The imagePRESS Lite C170 Main Unit requires a dedicated single-phase
208V/15A NEMA 6-15R receptacle for proper operation.
The imagePRESS Lite C165 Main Unit requires a dedicated single-phase
120V/20A NEMA 5-20R receptacle for proper operation.
Table 19Power Receptacle
imagePRESS Lite C170 Main Unit imagePRESS Lite C165 Main Unit
NEMA 6-15 Receptacle
NEMA 5-20 Receptacle
Accessories / Controllers
NEMA 5-15 Receptacle