37
- Header 1 (Common for data format 2,3)
OL : OVER LOAD, UNDER LOAD
ST : Stable indicator
US : Unstable indicator
- Header 2 (Common for data format 2,3)
NT : NETWEIGHT (actual weight)
GS : GROSS WEIGHT (gross weight)
- Data about numbers (Common for data format 2,3)
2B(H) : “+” PLUS
2D(H) : “-” MINUS
2O(H) : “ ” SPACE
2E(H) : “ ” Decimal point
- UNIT (Common for data format 2,3)
- Kg
- t
- g
Data format(2)
,
,
,
Data(8)
K
g
CR
LF
- Equipment ID : Set in F34
- Lamp Status: Display of ON/OFF status in the current lamp
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
1
Stable
1
Hold
Print
Gross
weight
Tare
Zero
- Connection with PC (Personal Computer) and other devices
Header1
Header2
Equipment ID
Lamp Status
Blank
unit
INDICATOR
PC
9 PIN(Base)
PERSONAL
COMPUTER
9 PIN(기준)
GND(5 pin) GND (5Pin)
RxD(2 pin) TXD (3Pin)
TXD(3 pin) RXD (2Pin)