21
F-FUNCTION LIST
Function
default
Details
Division
01
2
DECIMAL POINT SETTING
0, 0.0, 0.00 ,0.000
02
0
ZERO MEMORY MODE
Normal(0), Back-UP(1)
03
5
MOTION BAND RANGE
0~9
04
5
ZERO TRACKING RANGE
0~9
05
0
AUTO ZERO RANGE SETTING
00~99
06
15
DIGITAL FILTER RANGE
01~49
07
0
ZERO,TARE KEY OPERATION
MODE
0) during the stable period ,
1) during the instable period
08
3
ZERO KEY OPERATION RANGE
SETTING MODE
2%(0),5%(1),10%(2),20%(3),100%(4)
09
3
TARE KEY OPERATION RANGE
SETTING MODE
10%(0),20%(1),50%(2),100%(3)
10
0
HOLD FUNCTION SETTING
Peak-hold(0),Sample hold(1)
5 second average hold (2)
11
3
EXTERNAL RELAY INPUT SETTING
0,1,2,3,4
12
0
FRONT KEY OPERATION SETTING
0,1,2,3,4
13
0
CODE NUMBER ASSIGNING
0,1,2
14
0
HOLD OFF TIME
0.0 ~ 9.9 seconds
21
1
WEIGHING MODE SELECTION
1,2,3,4
22
10
COMMUNICATION OUTPUT DELAY
TIME(T1) SETTING
0.0 ~ 9.9 seconds
24
10
DELAY TIME OF RELAY OUTPUT
FOR THE WEIGHING JUDGMENT
0.0 ~ 9.9 seconds
25
10
ON TIME OF RELAY OUTPUT FOR
THE WEIGHING JUDGMENT
0.0 ~ 9.9 seconds
30
0
SERIAL PARITY BIT SETTING MODE
NO(0), ODD(1), EVEN(2)
31
7
BAUD RATE FOR SERIAL
COMMUNICATIONS
0~9 , 115200 bps ~ 2400 bps
32
0
SERIAL COMMUNICATION MODE
0 : Stream Mode, 1: Stable Mode,
33
1
SERIAL COMMUNICATION MODE
0: Unilateral Transmission Mode
1: COMMAND Mode,
2: LCD Mode
4: External Display Mode
34
1
EQUIPMENT ID NUMBER SETTING
1~99
35
0
TRANSMISSION DATE FORMAT
0: BASIC FORMAT,
1: CAS FORMAT
36
0
BCC SELECTION MODE
0: BCC not used
1: BCC used
37
3
DATA TRANSFERENCE
COUNT SETTING
0~6
40
0
Weight Unit
selection (Communication)
0: kg, 1: g, 2: ton

Table of Contents