23
F-FUNCTION DESCRIPTIONS IN DETAIL
( : Factory Default)
Decimal Point Setting
F01
0
No decimal point
0
1
A place of decimals
0.0
2
2 places of decimals
0.00
3
3 places of decimals
0.000
Zero Memory Mode
F02
0
Normal Mode
1
Back-up Mode
* The weight on the indicator is not stored in the Normal Mode during any blackout or power-off.
Accordingly, the power should be turned on after the weighing object is removed from the indicator.
* 0 is immediately shown on the display in the Back-up Mode by reading the stored zero point
when the power is turned on. Therefore, the weight is shown during any blackout or power-off if
there is any weighing object on the indicator if the power is turned on.
Motion Band Range Setting
F03
5
0
9
A function to set how much the range of variations for
weight per hour is set for the stable status.
0 : With less vibration (weak) ~ 3: With more vibration
(strong)
* It is a function to stabilize the state when the range of variations for weight in the set time does not
go over the A/D Count set range.
There are subtle vibrations in general when a weighing object is placed on the indicator.
Hence, the state indicator Stable is turned on the display once the vibration is stabilized.Motion
Band sets the time range to stabilize the vibration in this way.