46
4~20mA(0~10V) Serial Interface(Option)
No.
Name
Use
1
OUT
Current or Voltage Output Port
5
COM
Common Output port
1 5
- F-83 (Parts related to the analog output)
Set Max. Analog Output Value
F83
Maximum analog output of 0 ~ 10V, 4 ~ 20mA can be set.
Ex) If 1000 is set, the output of 10V or 20mA is done when the weight value reaches
1000.
- While Key Test Mode in TEST2 in relation with the analog setting;
press Key for the output of 4mA(or 0V).
press Key for the output of 12mA(or 5V).
press Key for the output of 20mA(or 10V).
press Key to move to Test. (EXIT)