181
3.3.3 How to Clear Tare
Remove the item from the platter
Press “TARE” key again.
3.3.4 Preset Tare
Call up a PLU including tare(weight of container).
EX) PLU #3 s tare =150 g
Clear PLU#3, then tare is also automatically cleared.
3.3.5 Successive Tare
Enter tare (weight of container) using
numeric keys.
EX) 150 g
Enter the weight of container using
numeric keys.
EX) 200 g
Press “TARE key after removing item and container from the platter.
Note: Parameter 605 “Accumulation Tare” and parameter 606 “Subtraction
Tare” must be set.