3-CONTROLS/INSTRUMENTS
Suspendingautomaticregeneration
4FKEJV-001ZA3
AutomaticregenerationissuspendediftheDieselParticulateDiffuserswitchispressedduringregeneration.
Iftheswitchisheldfor3secondsormoreduringautomaticregeneration,operationmovestooptionalmanualregen-
eration.(Theorangelampblinks.)
Donotpresstheswitchagainifmanualregenerationisnotwanted.
Theorangelampgoesout.
Thediffusermaybecomefaultyifoperationiscontinuedwhenautomaticregenerationissuspendedforalongtime.
Movetoasafeplaceasquicklyaspossibleandexecuteregeneration.Operationchangestomanualregenerationif
automaticregenerationissuspendedforalongtime.
1.Inautomaticregeneration
Thegreenlampislit.
Thefollowingmessageisdisplayedcyclically.
AutoDPDRe-gen
2.Carryouteitherofthefollowing.
Settingthefunctioncancellationlevertothelockposition.
Pressingtheswitch.
PushDPDswitchtoactivate