Loading...
Transmit Value Receive Value Parameter
(LSB, MSB)
- (00H, 00H) - (1FH, 00H) -256
- (20H, 00H) - (3FH, 00H) -255
- (40H, 00H) - (5FH, 00H) -254
- (60H, 00H) - (7FH, 00H) -253
- (00H, 01H) - (1FH, 01H) -252
: : :
- (00H, 40H) - (1FH, 40H) 0
: : :
- (60H, 7EH) - (7FH, 7EH) +251
- (00H, 7FH) - (1FH, 7FH) +252
- (20H, 7FH) - (3FH, 7FH) +253
- (40H, 7FH) - (5FH, 7FH) +254
- (60H, 7FH) - (7FH, 7FH) +255
39.23 Envelope Clock Trigger Setting Value Table
Transmit Value Receive Value Parameter
MSB
- 00H - 05H off
- 06H - 0CH 1/4 beat
- 0DH - 13H 1/3 beat
- 14H - 19H 1/2 beat
- 1AH - 20H 2/3 beat
- 21H - 27H 1 beat
- 28H - 2EH 3/2 beat
- 2FH - 34H 2 beat
- 35H - 3BH 3 beat
- 3CH - 42H 4 beat
- 43H - 49H 1/4 upbeat
- 4AH - 4FH 1/3 upbeat
- 50H - 56H 1/2 upbeat
- 57H - 5DH 2/3 upbeat
- 5EH - 64H 1 upbeat
- 65H - 6AH 3/2 upbeat
- 6BH - 71H 2 upbeat
- 72H - 78H 3 upbeat
- 79H - 7EH 4 upbeat
39.24 Filter Cutoff Setting Value Table