Part III
System Message
11 Timing Clock
Message Format: F8H
Send Sent perio dically when the MIDI syn mode is master.
Receive Receipt while the MIDI sync mode is slave causes tempo to be synced based in timing clock
information.
12 Start
Message Format: FAH
Send Sent when the Step Sequencer is started while the MIDI sync mode is master.
Receive Receipt while the MIDI sync mode is slave starts Auto Accompaniment play upon receipt of
the next sent timing clock (F8H).
13 Stop
Message Format: FCH
Send Sent when the Step Sequencer is stopped while the MIDI sync mode is master.
Receive Receipt while the MIDI sync mode is slave stops Auto Accompaniment play.
14 Active Sensing
Message Format: FEH
Send Sent perio dically when the MIDI syn mode is master.
Receive Once this message is received, the Active Sensing mode is entered. If no MIDI message is
received for a specified amount of time, voices being sounded by this Instrument’s sound source are
released, the controller is reset, and the Active Sensing mode is exited.
39

Table of Contents

Other manuals for Casio XW-P1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Casio XW-P1 and is the answer not in the manual?

Casio XW-P1 Specifications

General IconGeneral
Polyphony64 notes
ArpeggiatorYes, 6 types
Power SupplyD batteries x 6, AC Adapter
Dimensions95.7 x 39.7 x 11.1 cm
Weight13.2 lbs
EffectsReverb, Chorus, Delay, Distortion, Rotary Speaker
DisplayLCD
User Tones100
Inputs/OutputsUSB
User memory100 user tones
ControllersPitch Bend Wheel, Modulation Wheel
InputsLine In
Outputs1/4" L/Mono, R output
Keyboard61 keys
ConnectionsUSB

Related product manuals