21
- Shift the mains switch into the “0FF” position
- Plug the grounding (earthing) cable into the grounding (earthing) socket / “plus”
current socket (17) and twist it to fasten it
- With the other end of the grounding (earthing) cable, establish a connection to the
workpiece
- Shift the mains switch into the “0FF” position
- Plug the welding cable of the TIG torch into the welding torch current socket /
“minus” current socket (16) and twist it clockwise to latch it into place
- Connect up the torch shielding-gas hose to the gas “quick-connector” (23)
- Plug the control plug of the welding torch onto the torch control connection (19) and
twist it to fasten it
- Tool up the welding torch (see the instruction manual for the torch)
Only when using a water-cooled torch and cooling unit:
- Plug in the welding-torch water connectors to the water forward-flow (black) and
return-flow (red) connections on the cooling unit.
When using a TIG welding torch with an integral gas connector:
- On the rear of the power source, connect the pressure regulator to the Shielding
gas connection socket (22) by means of the gas hose
- Tighten the swivel nut
Connecting up
the gas cylinder
(continued)
Establishing a
connection to the
workpiece
Mounting the