54
1702 AC/DC 2202 AC/DC
Mains voltage 230 V 230 V
Mains voltage tolerance -20% / +15% -20% / +15%
Mains fuse protection (slow-blow) 16 A 16 A
Primary contin. power (100% d.c.) 3.0 kVA 3.0 kVA
Cos phi 0.99 0.99
Welding current range
WIG 3 - 170 A 3 - 220 A
Elektrode 10 - 140 A 10 - 180 A
Welding current at:
10 min/25°C (77°F) 35% d.c. 170 A -
10 min/25°C (77°F) 40% d.c. - 220 A
10 min/25°C (77°F) 60% d.c. 120 A 180 A
10 min/25°C (77°F) 100% d.c. 100 A 150 A
10 min/40°C (104°F) 30% d.c. 170 A 220 A
10 min/40°C (104°F) 60% d.c. 110 A 160 A
10 min/40°C (104°F) 100% d.c. 90 A 130 A
Open-circuit voltage 90 V 93 V
Working voltage:
TIG 10.1 - 16.8 V 10.1 - 18.8 V
Rod electrode (MMA) 20.4 - 25.6 V 20.4 - 27.2 V
Degree of protection IP 23 IP 23
Type of cooling AF AF
Insulation class B B
Dimensions L x W x H mm (with handle) 500/175/410 500/175/410
Weight 15 kg 17.3 kg
Marks of conformity S, CE S, CE
Technical data
Note! Inadequately dimensioned electrical installations can lead to serious
damage. The mains supply lead, and its fuse protection, must be dimensioned
accordingly. The technical data shown on the rating plate shall apply.
CastoTIG 1702
AC/DC / 2202 AC/
DC
Special voltages