24
cdvi.com
cdvigroup.com
DIGIWAY PLUS
INSTALLATION MANUAL
EN
Menu Service
The unit is equipped with 2 cycle counters : Absolute Counter and Partial Counter
The Absolute Counter registers the cycles of the motor for all its life : It cannot be reset except by the factory.
The counter increments by 1 if the door makes a clean cycle of opening+pause+closing without any obstacle or re-opening action caused by a
sensor ( radar, photocells, etc.).
The current value of the absolute counter can be seen on the menu INFORMATION : see next page
The Partial Counter can be used to set a maintenance period. It can be reset after a service intervention.
MENU MAIN
SERVICE
SERVICE
COUNTER
SERVICE
THRESHOLD
SERVICE
CHANGE PASSWORD
SERVICE
RESET COUNTER
COUNTER
0
PASSWORD
1111
THRESHOLD
0500
PASSWORD
1111
CONFIRM SERVICE
RESET COUNTER?
PASSWORD
1111
NEW PASSWORD
0000
CONF PASSWORD
0000
NOTES
(1) : Partial counter value;
(2) : Threshold : is the N° of cycles after which the unit starts to give the Service request message : the main led ashes RED SLOWLY
Its setting requires to dial the right 4-digits System Password.
If Threshold=0 ( factory setting ) the main led never changes colour.
(3) : Resets the partial counter value : it has to be reset after the maintenance intervention and resets the main led to SOLID GREEN.
This requires the 4 digit system password to be entered.
(4) : Changing the system password: FACTORY VALUE = 1111
To change the password rst requires the default or current password to be entered. When changing the password the new password must
re-entered to conrm.
(1)
(2)
(3)
(4)