Maintenance
An automatic door, realized through the installation of the operator DIGIWAY PLUS, needs periodic checks ( at least
every 12 months ) as listed in the following points:
1) Check the door balancing and the perfect functionality of the hinges;
2) sliding arm:
2A) Check the xing solidity of the sliding guide to the door and his horizontal alignment;
2B) Check the uency of the sliding block;
2C) Check drive shaft bolt is tight;
2D) Check the correct coupling arm-motor shaft ( solidity of the driving pins );
2E) Possible cleaning of the guide;
3) articulated arm:
3A) Check the xing of the bracket to the door;
3B) Check the solidity of the articulated arm knee;
3C) Check drive shaft bolt is tight;
3D) Check the solidity of the adjustable forearm (2 screws M5 x 12);
4) Check the xing of the motor to the backplate and the backplate to the wall;
5) Check the absence of frictions along the run of the door ;
6) Check of the functionality of the peripherals (radar, electrolock or magnet);
7) In the case of double door with overlapping, check of the perfect synchronization of the 2 leaves;
8) Possible replacement of the battery if the led LP gives the proper message.