USE OF THE DEVICE
ORIGINAL INSTRUCTIONS 121
4.1.1.3 External beacon
The external beacon has coloured light modules which light up to indicate the following statuses
(the coloured light modules actually present depend on the beacon supplied):
Model
THS/FBB THS/FB THS/MBB THS/M65 THS/MBR
a
RED Fault present
    
b
AMBER
Detection alarm
present
 
c
BLUE Test request
d
Buzzer External horn
   

Standard

Option / Accessory
If you dismantle the beacon modules, they must be refitted in the original order.
THS/FBB systems have a single red module which lights up to indicate an alarm or a fault.
Light Meaning Light indication
a
RED
No alarm or fault present Off
An emergency or fault to be reset Slow flashing
Emergency indication Fast flashing
b
AMBER
No alarm present Off
Detection alarm present
1
On fixed
Waiting for manual alarm reset
2
Slow flashing
c
BLUE
No test request present Off
Test request present Slow flashing
1
Programmable. See the Programming Manual
2
In the ejection modes with belt locked
4.1.2 Acoustic indicators
Systems fitted with a Control Power Box and Conveyor Control System have an internal acoustic
warning device (buzzer) which sounds to indicate a fault or metal detection.
The external beacon, by default, sounds only to indicate faults, but can also be programmed to
sound when the detector detects metal fragments. In this case refer to the Programming Manual for
more information.