4
Maintenance
141
Maintenance
Items S/N Work content Technical requirements
Suspension
system
2 Check the shock
absorber
It is firmly installed without oil
leakage and works effectively.
The support shall be free of
cracks, the rubber bushing of the
shock absorber shall be intact,
and the shock absorber fixing
bolts shall be fastened.
3 Check stabilizer
bar
It is firmly installed, and the
rubber pad is intact, and there
is no crack.
Electrical
box and
fuse
4 Check the central
electrical box (in
the instrument
panel access
hole or the
driver's lower
compartment or
the driver's rear
electrical
compartment)
It is forbidden to use non-
standard fuse and relay;
all fusible wires cannot be
replaced by wires; it is
forbidden to pull wire harness,
modify wire harness and install
other electrical appliances
without permission.
Frame,
body and
accessories
5 Inspect
fasteners
They shall be reliable in
performance and work well
without deformation, fracture,
desoldering. The connecting
bolts and rivets are firm.

Table of Contents