SOLOY TURBINE PAC SECTION 4
POHS CESSNA T206H/206H NORMAL PROCEDURES
4-9
F.A.A. Approved November 17, 2015
6. TOT and N
1
MONITOR TOT (810 to 927C), 10 seconds
maximum and N
1
for normal acceleration.
7. Propeller (N
P
) CHECK rotating by 25% N
1
.
8. Transmission Oil Pressure POSITIVE indication at completion
of the start.
9. Start Switch RELEASE at 58% N
1
.
10. Generator Switch ON.
11. N
1
CHECK 59% MINIMUM. If not, turn off generator and add
power to 70% N
1
, then turn on generator.
12. Lights As required
13. Avionics As required
14. Wing Flaps UP
STARTING ENGINE (With External Power)
1. Propeller CLEAR
2. TOT 150C or Lower
3. External Power CONNECT to airplane receptacle
NOTE
TOT can readily be reduced to 150°C by motoring
the starter.
4. Start Motor Switch MOTOR and hold to 12 15% N
1
based on
temperatures listed below.
NOTE
Starter Duty Cycle is located in Amplified
Procedures.
5. Start Motor Switch START and HOLD to 58% N
1
Positive oil
PSI indication.
6. Fuel Cutoff Control RUN (IN) at:
N
1
RPM Temp C (F)
15% ........................................ Above 7 (45)
13% ................................ -18 to +7 (0 to 44)
12% ....................................... Below -18 (0)
7. TOT and N
1
MONITOR TOT (810 to 927C), 10 seconds
maximum and N
1
for normal acceleration.
8. Propeller (N
P
) CHECK rotating by 25% N
1
.
9. Transmission Oil Pressure POSITIVE indication at completion
of the start.
10. Start Switch RELEASE at 58% N
1
(within 25 to 60 seconds).
11. APU DISCONNECT.
12. Generator Switch ON.
13. N
1
CHECK 59% MINIMUM. If not, turn off generator and add
power to 70% N
1
, then turn on generator.
14. Lights As required
15. Avionics As required
16. Wing Flaps UP