20
Operations Product Manual - Orca
™
CO
2
Series MicroBulk Delivery System
5. Disconnect Bulk Transfer Hose from Vapor Balance
(DC-5).
6. Refer to “VII. Pump Delivery” for delivery
instructions.
Hydraulic Power Supply
With the Orca CO
2
securely positioned and ready for
delivery, follow these steps to start and use the power take-
o.
1. Engage PTO per heavy duty truck OEM’s
recommendation (if unknown, consult your local OEM
truck dealership).
a. Conrm provided instructions meet OEM truck
recommendations and can be easily understood by
all operators.
Note: DamagemayoccurtoPTOsystem or
transmissionifproperPTOengagementis
notfollowed.Itishighlyrecommendedto
develop instructions and place a label on
the dash.
2. Set speed to desired operating speed.
Note: Labelincabshoulddeterminethemax
engine speed.
Note: ManyOEMtruckshavedierentways
toachieveoperatingspeed.Conrm
providedinstructionsmeetOEMtruck
recommendations and can be easily
understood by all operators.
Warning! If excessive vibration is noticed,
contact your local heavy duty
truck service provider. Failure
to do so may result in additional
damage or loosening of moving
components.
Methods to Stop Pump
Primary
• Switch on Gauge Panel
• Truck PTO Dash Switch
• Truck Key