NVF5 Series User Manual Appendix B Parameter list
Code
Name
Setting Range
Default
Change
Thousands Place : External
Fault-
E.EF (
Same as ones
place)
FE.39
Protection Selection2
in Fault Mode
0x0000 ~ 0x2222
Ones Place:Comm. Abnormal
-E.CE
0:Coast Stop
1:Stop per Stop Mode
2:Keep Running
Tens Place:Reserve
Hundreds Place :
EEprom
Abnormal-E.EEP
0:Coast Stop
1:Stop per Stop Mode
Thousands Place
:
Reserve
0x0000
○
FE.40
Protection Selection3
in Fault Mode
0x0000 ~ 0x2222
Ones Place:Load Loss-E.LL
0:Coast Stop
1:Decel. Stop
2 :
Keep Running by
Skipping to 7% Motor Rated
Frequency,Recover to setting
frequency when load recover
Tens Place:
PID Feedback Loss
in Running Mode-E.FbL
0:Coast Stop
1:Stop per Stop Mode
2:Keep Running
Hundreds Place : Excessive
Speed Deviation
- E.dEv(Same
as tens place)
Thousands Plac :
Motor Over
Speed-E.OS (
Same as tens
place)
0x0000
○
FE.41
Protection Selection4
in Fault Mode
0x0000 ~ 0x2222
Ones Place:Reserve
Tens Place:Reserve
Hundreds Place:Reserve
Thousands Plac
:
Reserve
0x0000
○
FE.42
Protection Selection5
in Fault Mode
0x0000 ~ 0x2222
Ones Place:Reserve
Tens Place:Reserve
Hundreds Place:Reserve
0x0000
○