MT2484A
Feeder Fill Clock
The Feeder Fill Clock controls the fill system that supplies the house feeders Male or Female.
The list of Feeder Fills is determined by what was setup in the Setup/Outputs/Clock screen.
The Feeder Fill Clock follows the Feed Day/Non Feed Day schedule of the Feed Clock assigned to in the
Feeding System Matrix (Feed System Screen).
1.Reset All Presets: Select this button to Reset all Fill system presets. A Preset is a specific amount of feed
needed to be delivered on a Feed day.
2.Fill Clocks: Select the Fill Clock needed to setup.
3.On-at: The time of day that an event will start.
4.Off-at: The time of day (hours:minutes:seconds) that an even will run.
5.Run-for: The total time in (hours:minutes:seconds) that the Feeder will run.
6.Events: The desired number of timed events. The maximum number is 24.
7.Use Preset: From the dropdown select Yes or No.
A Preset is a specific amount of feed needed on a Feed day. Used with all Scale systems.
8.Preset: Enter the amount of feed needed for next day feeding.
9.Reset Preset: This button is used to Manual Reset the Preset for the next day feeding.
Note: Follow the same steps to setup all Feeder Fill Clocks. Caution! Do not allow Weigh Fill and Feeder
Fill Times to Overlap.
1
2
3
4
5
6
7
8
9

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Chore-Time Tronics 3 and is the answer not in the manual?

Chore-Time Tronics 3 Specifications

General IconGeneral
BrandChore-Time
ModelTronics 3
CategoryControl Unit
LanguageEnglish

Related product manuals