8. Battery Test
This function is test battery discharge by setting a fixed load and checking the battery output
voltage after loading started. Once the voltage is adjusted to a certain cutoff potential, stop
loading and calculate the total electric charge (mA-hour). The entire battery discharge
status can be seen from the Battery Voltage and Current Reading Chart.
Figure 8-1 Battery Test Window
8.1 Operation Mode
It sets the operation mode to Normal or Program.
Normal Mode
Figure 8-2 Selecting Operation Mode
8.1.1 Normal Mode
If the Operation Mode is set to Normal it indicates the load is a fixed value that will not
changed as time goes.