Switch to enable Code 11 decoding.
Set whether to verify check digits according to the
selected option. If the check digits are incorrect, the
barcode will not be accepted.
Disable
One Check Digit
Two Check Digit
Selects whether to include check digits in the transmitted
data.
“Check Digit Option” must be enabled.
Sets the length of the Code 11 symbols to decode.
One Fixed length (Length 1)
Two Fixed lengths (Length 1>Length 2)
Max / Min Length (range: 0-55; Length 1<Length 2)
Any Length
Switch to enable Code 39 decoding.
Selects whether to convert decoded data to Italian
Pharmacode.
Prefix character “A” to Code 32 barcodes.
“Convert to Code 32” must be enabled for this to function
properly.
Selects whether to verify the Modulo 43 check digit. If the
check digit is incorrect, the barcode will not be accepted.
Decide whether to include the check digit in the data to
transmit.
“Verify Check Digit” must be enabled.
Selects whether to enable Code 39 Full ASCII decoding.
Characters are paired to encode the full ASCII character
set.
Sets the length of the Code 39 symbols to decode.
One Fixed length (Length 1)
Two Fixed lengths (Length 1>Length 2)
Max / Min Length (range: 0-55; Length 1<Length 2)
Any Length
Select the security level from Level 0 to Level 3