EasyManua.ls Logo

Cisco 2950G 24 - Catalyst Switch - Configuring and Using Interface-Range Macros

Cisco 2950G 24 - Catalyst Switch
648 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9-8
Catalyst 2950 Desktop Switch Software Configuration Guide
78-14982-01
Chapter 9 Configuring the Switch Interfaces
Using the Interface Command
Configuring and Using Interface-Range Macros
You can create an interface-range macro to automatically select a range of interfaces for configuration.
Before you can use the macro keyword in the interface range macro global configuration command
string, you must use the define interface-range global configuration command to define the macro.
Beginning in privileged EXEC mode, follow these steps to define an interface-range macro:
Use the no define interface-range macro_name global configuration command to delete a macro.
When using the define interface-range global configuration command, note these guidelines:
Valid entries for interface-range:
vlan vlan-ID - vlan-ID, where VLAN ID is from 1 to 1005 with the SI installed or 1 to 4094
with the EI installed
fastethernet slot/{first port} - {last port}, where slot is 0
gigabitethernet slot/{first port} - {last port}, where slot is 0
port-channel port-channel-number - port-channel-number, where port-channel-number is
from 1 to 6.
You must add a space between the interface numbers and the hyphen when entering an
interface-range. For example, fastethernet 0/1 - 5 is a valid range; fastethernet 0/1-5 is not a valid
range.
The VLAN interfaces must have been configured with the interface vlan command. The show
running-config privileged EXEC command output shows the configured VLAN interfaces. VLAN
interfaces that do not appear by using the show running-config command cannot be used as
interface-ranges.
All interfaces in a range must be the same type; that is, all Fast Ethernet ports, all Gigabit Ethernet
ports, all EtherChannel ports, or all VLANs, but you can combine multiple interface types in a
macro.
Command Purpose
Step 1
configure terminal Enter global configuration mode.
Step 2
define interface-range macro_name
interface-range
Define the interface-range macro, and save it in NVRAM.
The macro_name is a 32-character maximum character string.
A macro can contain up to five comma-separated interface
ranges. You do not need to enter spaces before or after the comma.
Each interface-range must consist of the same port type.
Step 3
interface range macro macro_name Select the interface range to be configured by using the values saved
in the interface-range macro called macro_name.
You can now use the normal configuration commands to apply the
configuration to all interfaces in the defined macro.
Step 4
end Return to privileged EXEC mode.
Step 5
show running-config | include define Show the defined interface-range macro configuration.
Step 6
copy running-config startup-config (Optional) Save your entries in the configuration file.

Table of Contents

Related product manuals