EasyManuals Logo

Cisco 2950G 24 - Catalyst Switch User Manual

Cisco 2950G 24 - Catalyst Switch
648 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #248 background imageLoading...
Page #248 background image
9-20
Catalyst 2950 Desktop Switch Software Configuration Guide
78-14982-01
Chapter 9 Configuring the Switch Interfaces
Monitoring and Maintaining the Interfaces
Use the no shutdown interface configuration command to restart the interface.
This example shows how to shut down Fast Ethernet interface 0/5:
Switch# configure terminal
Switch(config)# interface fastethernet0/5
Switch(config-if)# shutdown
Switch(config-if)#
*Sep 30 08:33:47: %LINK-5-CHANGED: Interface FastEthernet0/5, changed state to a
administratively down
This example shows how to re-enable Fast Ethernet interface 0/5:
Switch# configure terminal
Switch(config)# interface fastethernet0/5
Switch(config-if)# no shutdown
Switch(config-if)#
*Sep 30 08:36:00: %LINK-3-UPDOWN: Interface FastEthernet0/5, changed state to up
To verify that an interface is disabled, enter the show interfaces privileged EXEC command. A disabled
interface is shown as administratively down in the show interfaces command output.
The shutdown command shuts down the LRE link when applied to an LRE interface. To shut down the
Fast Ethernet port(s) on the CPE device use this command in interface configuration scope:
cpe shutdown [port <num>]
Step 4
end Return to privileged EXEC mode.
Step 5
show running-config Verify your entry.
Command Purpose

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco 2950G 24 - Catalyst Switch and is the answer not in the manual?