7-31
Firepower 7000 and 8000 Series Installation Guide
Chapter 7 Hardware Specifications
Firepower 8000 Series Devices
Fiber 10GBASE
non-bypass
MMSR or SMLR NetMod
Quad-port fiber non-bypass interfaces with LC connectors
Cable and distance:
LR is single-mode at 5000 m (available)
SR is multimode fiber (850 nm) at 550 m (standard)
Fiber 1000BASE-SX
non-bypass NetMod
Quad-port fiber non-bypass interfaces 1000BASE-SX with LC connectors
Cable and distance:
SX is multimode fiber (850 nm) at 550 m (standard)
Power supply 82xx Family: Dual 750 W redundant power supplies designed for AC or DC.
AC Voltage: 100 VAC to 240 VAC nominal (85 VAC to 264 VAC
maximum)
AC Current: 8A maximum over the full range, per supply
4A maximum for 187 VAC to 264 VAC, per supply
AC Frequency range: 47 Hz to 63 Hz
DC Voltage: -48 VDC nominal referenced to RTN
-40 VDC to -72 VDC maximum
DC Current: 18A maximum, per supply
83xx Family: Dual 1000 W redundant power supplies designed for AC or DC.
AC Voltage: 100 VAC to 240 VAC nominal (85 VAC to 264 VAC
maximum)
AC Current: 11A maximum over the full range, per supply
5.5A maximum for 187 VAC to 264 VAC, per supply
AC Frequency range: 47 Hz to 63 Hz
DC Voltage: -48 VDC nominal referenced to RTN
-40 VDC to -72 VDC maximum
DC Current: 25A maximum, per supply
Operating temperature 82xx Family: 50°F to 95°F (10°C to 35°C)
83xx Family: 41°F to 104°F (5°C to 40°C)
Non-operating
temperature
-29
o
F to 158
o
F (-20
o
C to 70
o
C)
Operating humidity 5% to 85% non-condensing
Non-operating humidity 5% to 90%, non-condensing with a maximum wet bulb of 82°F (28°C) at temperatures from 77°F
to 95°F (25°C to 35°C)
Altitude 0 ft (sea level) to 6000 ft (0 to 1800 m)
Cooling requirements up to 2900 BTU/hour
You must provide sufficient cooling to maintain the appliance within its required operating
temperature range. Failure to do this may cause a malfunction or damage to the appliance.
Table 7-43 Firepower 82xx Family and Firepower and AMP 83xx Family Physical and Environmental Parameters
Parameter Description