Spanning Tree Protocol
Configuring Multiple Spanning Tree
Cisco 220 Series Smart Switches Administration Guide Release 1.1.0.x 158
12
- BackupThe port provides a backup path to the designated port path
toward the Spanning Tree leaves. Backup ports occur when two ports
are connected in a loop by a point-to-point link. Backup ports also occur
when a LAN has two or more connections connected to a shared
segment.
- DisabledThe port does not participate in the Spanning Tree.
Mode—Displays the current Spanning Tree mode.
- STP—Classic STP is enabled on the port.
- Rapid STP—RSTP is enabled on the port.
- MSTP—MSTP is enabled on the port.
Type—Displays the MSTP type of the port.
- Boundary—A Boundary port attaches MSTP bridges to a LAN in an
outlying region. If the port is a boundary port, it also indicates whether the
device on the other side of the link is working in RSTP or STP mode.
- InternalThe port is an internal port.
Designated Bridge ID—Displays the bridge ID number that connects the
link or shared LAN to the root.
Designated Port ID—Displays the priority and port ID on the designated
bridge that connects the link or the shared LAN to the root.
Designated Cost—Displays the cost of the port participating in the STP
topology. Ports with a lower cost are less likely to be blocked if STP detects
loops.
Remaining Hops—Displays the hops remaining to the next destination.
STEP 5 Click Apply. The Running Configuration is updated.

Table of Contents

Other manuals for Cisco SG220-26

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SG220-26 and is the answer not in the manual?

Cisco SG220-26 Specifications

General IconGeneral
ModelSG220-26
CategorySwitch
Ports24 x 10/100/1000 + 2 x Gigabit SFP
Switching Capacity52 Gbps
Forwarding Rate38.69 Mpps
LayerLayer 2
PoENo
MountingRack-mountable
MAC Address Table Size8K entries
Power SupplyInternal
ManagementWeb-based
Jumbo Frame Support9216 bytes
Operating Temperature0°C to 40°C (32° to 104°F)
Storage Temperature-20°C to 70°C (-4° to 158°F)
Humidity10% to 90%, non-condensing
Standards ComplianceIEEE 802.3, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3x, IEEE 802.1D, IEEE 802.1Q, IEEE 802.1p