8-5
Cisco SCE 2000 4xGBE Installation and Configuration Guide
OL-7824-06
Chapter 8 Troubleshooting
Troubleshooting Overview
Warning SCE 2000 is fully operational
(as above) but one of the
following occurred:
Line ports (GBE ports) to
the link are down
Management port link is
down
Temperature raised above
threshold
Voltage not in required
range
Fans problem
Power supply problem
Insufficient space on the
disk
Note Warning Note: If the
condition that caused the
SCE 2000 to be in
Warning state is resolved
(for example, link is up)
the SCE 2000 reverts to
Operational state.
Flashing orange
Warning Flashing orange
Failure System is in Failure state after
Boot due to one of the following
conditions:
Power on test failure
Three abnormal reboots in
less than 20 minutes
Platform configured to enter
Failure mode consequent to
failure-induced reboot (this
is configurable using CLI
command)
Note Depending on the cause
of failure, the
management interface
and the platform
configuration may or
may not be
active/available. Red
Red
Table 8-2 SCE 2000 Operational States
SCE 2000 Operational Status Description Status LED State

Table of Contents

Other manuals for Cisco SGE2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cisco SGE2000 and is the answer not in the manual?

Cisco SGE2000 Specifications

General IconGeneral
Jumbo Frame Support9KB
VLANsUp to 256
ManagementWeb-based, SNMP, CLI
StandardsIEEE 802.3, 802.3u, 802.3ab, 802.3z, 802.3x, 802.1D, 802.1Q, 802.1p, 802.1w
Dimensions440 x 44 x 257 mm
Power Supply100 to 240V AC, 50-60 Hz
Operating Temperature0°C to 40°C
Storage Temperature-20 to 70°C (-4 to 158°F)
Humidity10% to 90% non-condensing