© 1999-2017 Citrix Systems, Inc. All rights reserved. p.248https://docs.citrix.com
Generating the list of newnslog files to be processed...
Generating the events from newnslog files...
Checking for HDD errors...
Checking for HDD SMART errors...
Checking for Flash errors...
/var/nslog/dmesg.prev:* DEVELOPER mode - run NetScaler manually! *
******************************************
FOUND 1 Flash errors: DEVELOPER mode - run NetScaler manually
******************************************
Checking for SSL errors...
Checking for BIOS errors...
Checking for SMB errors...
Checking for MotherBoard errors...
Checking for CMOS errors...
License year: 2015: OK
License server failed at startup. Check /var/log/license.log
Vendor daemon failed at startup. Check /var/log/license.log
Checking for SFP/NIC errors...
Checking for Firmware errors...
Checking for License errors...
Checking for Undetected CPUs...
Checking for DIMM flaps...
Checking for LOM errors...
Checking the Power Supply Errors...
root@ns#
14. Important: Physically disconnect all ports except the LOM port, including the management port, from the network.
15. At the shell prompt, switch to the NetScaler command line. Type: exit
16. Run the following command to shut down the appliance: shutdown -p now
To upgrade the appliance
1. Power off the NetScaler appliance.
2. Locate two solid-state drives (SSDs) on the back of the appliance in slot #1 and slot #2, as shown in the following gure: