EasyManua.ls Logo

CITROEN C3 2003 - Checks: Air Supply Circuit XSARA PICASSO

CITROEN C3 2003
482 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
258
INJECTION
CHECKS : AIR SUPPLY CIRCUIT
Engines: RHY - RHZ
XSARA PICASSO
TOOLS
[1] Manual vacuum pump : FACOMM DA 16.
IMPERATIVE : Respect the safety and cleanliness requirements.
Vacuum pump.
- Connect the tool [1] on the vacuum pump (1).
- Start the engine.
- Pressure should be 0.8 bar at 780 rpm.
Boost pressure regulator electrovalve.
- Connect the tool [1] between the electrovalve (2) and the valve (3) of the boost pressure
regulator.
Compare readings with the values in the table below.
Pressure regulator valve.
- Connect the tool [1] on the valve (3).
- Appy a pressure of 0.5 bar to activate the rod "a" :
- Rod "a" should be moved 12 mm.
Engine speed (rpm) Pressure (Bar)
780 0.6
4000 0.25
B1HP12FD