EasyManua.ls Logo

CITROEN C4 2004 - Cooling System Specifications

CITROEN C4 2004
412 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
223
ENGINES
COOLING SYSTEM SPECIFICATIONS
Engines: KFU - NFU - RFJ - RFN - RFK
Engine type
Total capacity of the circuit
Radiator surface (dm
2
)
Pressurisation (Bars)
Opening of thermostatic
regulator
Alert
Cooling fan
Thermistat tightening torque
Connector colour
Ring seal colour
1.4i 16V 1.6i 16V 2.0i 2.0i 16V
KFU NFU RFJ RFN RFK
5,8 6,6 (*) 8,8 6,2 (1) – 6,6 (2) 6,6
(*) 6,8 (1) – 6,9 (2)
21
1,4
89°C
118°C
1x200 W 1x500 W 1x200 W 1x400 W
1,7 ± 0,2
Green
(*) = Automatic gearbox. - (1) = Climate 37°C.- (2) = Climate 45°C.