237
ENGINES
FILLING AND BLEEDING THE COOLING CIRCUIT
Fit the filling cylinder [1] and adaptor [2] assembly on the filling orifice.
Fill the cooling circuit.
NOTE: Keep the filling cylinder full to the maximum.
Start the engine.
Maintain an engine speed of 1600 rpm, up to the first cooling cycle (starting and stopping of the cooling fan).
Close each bleed screw as soon as the liquid starts to flow out without air bubbles.
Stop the engine.
Plug the filling cylinder [1], using the control rod [3].
Remove the filling cylinder [1], control rod [3] and adaptor [2] assembly.
Refit the header tank cap.
Checks.
Start the engine.
Maintain an engine speed of 1600 rpm, up to the first cooling cycle (starting and stopping of the cooling fan).
Stop the engine and wait for it to cool down.
Remove the header tank cap.
If necessary, top up the level to the maximum mark.
Refit the header tank cap.
B1GP0BTC
Engines: KFU - NFU - RFJ - RFN - RFK - RHR
UK-C4-page131-237-2004 15/11/04 9:19 Page 237