INJECTION
SPECIAL FEATURES: ADDITIVE SYSTEM
Sealing of the additive injector.
Couple tool [1] to the tube (1).
Action the manual pump [1].
WARNING: The additive injector should open at a pressure of 100 ± 20 Bars.
Action the manual pump in vacuum [1] at 800 m.bars.
WARNING: The value must not fall rapidly.
NOTE: Replace the fuel tank if the additive injector is defective.
Couple the tube (1).
Perform the actuator test «filling the tube: additive pump - additive injector», using LEXIA or
PROXIA.
C4BP1G7C
Checking the additive pump pressure and the sealing of the additive injector