Page 14 WS1CI & WS1.25CI Manual
OEM General Instructions
The control valve offers multiple procedures that allow the valve to be modifi ed to suit the needs of the installation. These
procedures are:
OEM Cycle Sequence
OEM Softener System Setup
OEM Filter System Setup
Installer Display Settings
User Display Settings
• Diagnostics
• Valve History
Once the OEM Cycle Sequence has been set, the other procedures can be accessed in any order. Details on each of the procedures
are provided on the following pages.
At the discretion of the manufacturer, the fi eld technician can access all settings. To “lock out” access to diagnostic and valve
history displays and modifi cations to settings except hardness, day override, time of regeneration and time of day by anyone but
the manufacturer, press , NEXT, , and SET CLOCK in sequence after settings are made. To “unlock”, so other displays can be
viewed and changes can be made, press , NEXT, , and SET CLOCK in sequence.
When in operation normal user displays such as time of day, volume remaining before regeneration or days remaining before
regeneration are shown. When stepping through a procedure, if no buttons are pressed within fi ve minutes, the display returns to a
normal user display. Any changes made prior to the fi ve minute time out are incorporated. The one exception is current fl ow rate
display under the diagnostic procedure. The current fl ow rate display has a 30 minute time out feature.
To quickly exit OEM Softener Setup, OEM Filter Setup, Installer Display Settings, Diagnostics or Valve History press SET
CLOCK. Any changes made prior to the exit are incorporated.
When desired, all information in Diagnostics may be reset to zero when the valve is installed in a new location. To reset to
zero, press NEXT and buttons simultaneously for 3 seconds and release. Press and simultaneously for 3 seconds to
reset diagnostic values to zero.
Sometimes it is desirable to have the valve initiate and complete two regenerations within 24 hours and then return to the preset
regeneration procedure. It is possible to do a double regeneration if the control valve is set to “NORMAL” or “NORMAL + on 0” in
OEM Softener System Setup or OEM Filter System Setup. To do a double regeneration:
1. Press the “REGEN” button once. REGEN TODAY will fl ash on the display.
2. Press and hold the “REGEN” button for three seconds until the valve regeneration initiates.
Once the valve has completed the immediate regeneration, the valve will regenerate one more time at the preset regeneration time.