RADIUS SL 860 07.2019 en 44
10.17 Override valve, electromagnetic, 1-sided, without pressure relief valve
Figure 38 Spare parts Override valve, electromagnetic, 1-sided, without pressure relief valve
Note:
The connection marked * is located on the RADIUS itself. The hose must be pressed at this
connection. (see 10.4, items 6, 7 and 22)
The hydraulic hose CW700.033800 (item no. 5) is also connected to the RADIUS itself. (see
10.4, item 10)
Note:
When ordering hydraulic hoses, measure the length "L" (including pressed fittings) and indicate
in mm (Conversion aid: 1” = 25.4 mm).
6
8
7
8
9
14
13
4.7
4.5
B
14
11
4.1
2
12
*
A
1
5
9
3.2
4.8
4.3
4.4
4.2
4.6
4.6
3.1
15
A = Return oil hose RADIUS
B = Return oil hose