98-175666-D Appendix F: Event messages F-11
List of events
0A285-0 Antenna INFO Azi Motor Over
current fault
Over current protected activated. Check
free movement of antenna.
0A286-0 Antenna ERROR Azi Motor No
response
No communication with motor. Check
cable.
0A300-0 Antenna ERROR Xel Motor prod
data
Internal production data invalid.
0A301-0 Antenna ERROR Xel Motor ZRM No zero reference found. Check from
motor to ZRM and free movement of the
antenna.
0A380-0 Antenna ERROR Xel Motor Driver
fault
Driver could not move antenna. Check
free movement of the antenna.
0A381-0 Antenna ERROR Xel Motor Power
fault
No power to motor driver. Check input
power to system.
0A382-0 Antenna ERROR Xel Motor
Shutdown
Internal error. Motor is shut down.
0A383-0 Antenna WARNING Xel Motor Over
temperature
warning
Motor temperature too high.
0A384-0 Antenna ERROR Xel Motor Over
temperature
fault
Motor temperature too high. Motor shut
down.
0A385-0 Antenna INFO Xel Motor Over
current fault
Over current protected activated. Check
free movement of antenna.
0A386-0 Antenna ERROR Xel Motor No
response
No communication with motor. Check
cable.
0A400-0 Antenna ERROR Ele Motor prod
data
Internal production data invalid.
0A401-0 Antenna ERROR Ele Motor ZRM No zero reference found. Check from
motor to ZRM and free movement of the
antenna.
0A480-0 Antenna ERROR Ele Motor Driver
fault
Driver could not move antenna. Check
free movement of the antenna.
0A481-0 Antenna ERROR Ele Motor Power
fault
No power to motor driver. Check input
power to system.
0A482-0 Antenna ERROR Ele Motor
Shutdown
Internal error. Motor is shut down.
ID Module Type Description Explanation
Table F-1: Event messages (Continued)