Installation
Block Up Converter Systems 6700/6900 series User Guide 35
Using short IF cables
Figure 11 shows the IF levels required when using short IF
cables such as the following:
5 m RG223
12 m 9914
15 m 9913F
•18m LMR-400
Figure 11: IF levels required for short cables
BUCIF cableModem
3 dB
BUC gain 
attenuator
setting
Gain
Input/output
level
16 dBm 19 dBm
19 dBm +
(BUC gain 
attenuator setting)
Refer to the relevant specifications sheets for the detailed specifications for your BUC