Installation
Block Up Converter Systems 6700/6900 series User Guide 43
1 Connect port 2 of the transmit RF waveguide switch to
the transmit flange of the antenna feed using gasket kits
and rigid or flexible waveguide as appropriate.
1 Connect the off-line BUC load to port 4 of the transmit
RF waveguide switch as shown in the mounting
drawings.
1 In transmit-only systems, fit the transmit-only connector
assembly to the LNB Switch Control connector.
1 Connect the transmit RF waveguide switch to the BUC
Switch Control connector using the cable supplied.
NOTE
If connecting the Ku-Band transmit RF
waveguide switch to a waveguide section
that has clearance holes for 6-32 UNC
hardware, a waveguide adaptor kit is
available.
CAUTION
Ensure all joints are completely
weatherproof.
NOTE
Spare flange kits are provided with the
redundancy package. The universal
Ku-Band flange kit contains a selection of
flat gaskets and circular cross-section
gaskets (both large and small
cross-sectional diameter).