Chapter 6 System Commands
© 2010 Colby Instruments. PDL-100A Operating and Programming Manual Page 55
REL RELAY COMMAND
The REL command sets the relay #x to ON (delay) or OFF (no
delay) state.
Command
Syntax
REL X ON | OFF
X = desired relay number 1 to 16. (0 sets ALL relays.)
ON = set relay X to ON
OFF = set relay X to OFF
NOTE: Relay numbering is from left to right. Relay # 16 (most
delay) is on the left, while relay # 1 is on the right (least delay).
Example
REL 8 ON
Returns
None
Programming
Example
HP : OUTPUT 705;"REL 1 ON"<NL>
NI : CWGPIB.Write “REL 1 OFF”