8.7 Value table
Parameter Value range Default Resolution R/S P/O
Speed C8600
fixed+measured C9100
0.5-50.0 m/min
0.5-80.0 m/min
3.0 0.1 m/min R/S P
Speed with C8600
encoder C9100
0.0-50.0 m/min
0.0-80.0 m/min
-
-
0.1 m/min R/S P
Step length of encoder 1.00 - 9.99 mm 1.00 0.01 mm S P
Distance measuring light barrier 10.0 - 99.9 mm 14.0 0.1 mm S P
Max.speed C8600
C9100
3 - 50 m/min
3 -100 m/min
50
80
1 m/min S P
Predispensing C8600
C9100
1 - 1000 mm 10.0
10.0
0.1 mm R/S P/O
Position 0 - 6000 mm 0 0.1 mm R/S P/O
Label scanner sensitivity 0 - 99 30 1 S P
Label length 5 - 2500 mm 100 1 mm S P
Label suppression 0 - 2500 mm 0 1 mm S P
Goods suppression 0 - 25000mm 0 1 mm S P
Adapter magnet time
(only C9100)
on/off
0.0 - 2.0s
off
0.0
-
0.1 s
S P
Labelling mode normal
multiple
delayed
on/off
on/off
on/off
on
off
off
-
-
-
S P
Multiple quantity
distance
2 - 24 pcs.
0 - 5000 mm
1
10
1 pcs.
1 mm
S P
Delayed stop at 1 - 250 mm 10 1 mm S P
Profiling factor
start
length
100 - 200 %
1 - 500 mm
1 - 500 mm
100
50
30
1 %
1 mm
1 mm
S P
Programs 1 - 32 1 - S P/O
Program identification 7 digits blank - S P
User levels 2 1 - S P/O
Password 0000 - 9999 0 - S P
Languages 9 De - S P/O
Direction of rotation left / right R - S P
Polarity IFEED pos. / neg. pos. - S P
Nonstop mode on/off off - S P
User menu 3 lines - any S P
Error handling 16 messages 0 any S P
Counter 999.999 - 1 R/S P/O
Preset counter 999.999 0 1 R/S P/O
Counter selection GSC, LSC, EXT LSC - S P
R = RUN S = STOP