InteliLite Global Guide
541
Related FW 1.2.1 Related applications AMF, MRS
Comm object 289
Description
Logical analog input designed for general value received from analog sensor. For more information about
wiring of analog inputs see Analog inputs on page 33. This analog input controls logical binary output
ANALOG SWITCH 16 (PAGE 484). The behavior of the switch depends on the adjustment of the setpoints
Analog Switch 16 On (page 249) and Analog Switch 16 Off (page 250).
IMPORTANT: This analog input has no protection. Input is designed only to control
appropriate logical binary output.
AIN Switch 16
6 back to Logical analog inputs alphabetically
Related FW 1.2.1 Related applications AMF, MRS
Comm object 290
Description
Logical analog input designed for general value received from analog sensor. For more information about
wiring of analog inputs see Analog inputs on page 33. This analog input controls logical binary output
ANALOG SWITCH 17 (PAGE 484). The behavior of the switch depends on the adjustment of the setpoints
Analog Switch 17 On (page 252) and Analog Switch 17 Off (page 253).
IMPORTANT: This analog input has no protection. Input is designed only to control
appropriate logical binary output.
AIN Switch 17
6 back to Logical analog inputs alphabetically
Related FW 1.2.1 Related applications AMF, MRS
Comm object 291
Description
Logical analog input designed for general value received from analog sensor. For more information about
wiring of analog inputs see Analog inputs on page 33. This analog input controls logical binary output
ANALOG SWITCH 18 (PAGE 485). The behavior of the switch depends on the adjustment of the setpoints
Analog Switch 18 On (page 255) and Analog Switch 18 Off (page 256).
IMPORTANT: This analog input has no protection. Input is designed only to control
appropriate logical binary output.
AIN Switch 18
6 back to Logical analog inputs alphabetically

Table of Contents

Other manuals for ComAp InteliLite MRS16

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ComAp InteliLite MRS16 and is the answer not in the manual?

ComAp InteliLite MRS16 Specifications

General IconGeneral
BrandComAp
ModelInteliLite MRS16
CategoryController
LanguageEnglish

Related product manuals