Low permeate water production.
Check status and functioning of inlet solenoid, if clogged, replace it.
Install a manometer on the pump outlet line to check operating pressure.
Treated water has a bad taste.
With the tap closed, the machine restarts for a few seconds.
Replace the check valve installed on the permeate line before max
pressure switch (install a manometer on permeate line and check
water pressure on permeate line).
Water leakage in hydraulic
circuit.
Look in the permeate hydraulic circuit for leakages (install a
manometer on permeate line and check water pressure on
permeate line).
With the tap opened, the machine doesn’t start
Check pressure switch functioning, if damaged replace it.
Check the wiring and the cable fixing to the terminals.
With the tap closed, the machine doesn't stop
Check pressure switch functioning, if damaged replace it.
With the tap opened, the machine works in discontinuous way.
Max pressure switch
calibrated at low pressure.
Calibrate the max pressure switch.