Fiber Low Power Carrier Access Point Installation Guide M0201ANC_uc
Page 58 © June 2019 CommScope, Inc.
Connect the Cables to the Fiber CAP L
4 Use a lint-free wipe drenched with isopropyl alcohol to clean the
connector winding.
5 Use a cotton bud drenched with isopropyl alcohol to clean the lip
of the inner ring.
6 Use a cotton bud drenched with isopropyl alcohol to clean the
inside surface of the inner ring.
7 Use a cotton bud drenched with isopropyl alcohol to clean the
inside of the center conductor spring tines.
8 Remove the protective caps from the unit connector, and then
clean it the same way that you cleaned the cable connector.