11.
K-Factor Settings
K-Factor Settings
A summary of the K-Factor settings can be seen below. Information on these settings and how
to change them can be found on the following pages.
Setting
Price display
Litres display
Dispenser settings
C-A or C-B
*******
Meter ID
ID-A or id-b
******
Temperature calibration
E-a or e-b
**.*
Density calibration
D15-a or d15-b
***.*
Maximum flow
QA **** or qb ****
K-Factor
FA or FB
***.****
Configuration code
C
*******
Comms
Cc
****
Solenoid delay
5da *** or 5db ***
Preset cutoff
Pca *.** or pcb *.**
Preset rounding
Prla*.** or prlb*.**
prxa*.** or prxb*.**
Flow time out
n-a *** or n-b ***
Using the Dispenser Menus
When changing settings on the dispenser, pressing the K-Factor switch in quick succession
cycles between the options available. The location of this switch can be found on page 7. Each
press of the button will cycle between the digits. When going through the menus, each menu
will cycle through the digits twice for ease of operation.
When a digit is flashing, hold down the relevant switch to increment this digit. Release the
switch on the desired value.
The system timeout is 10 seconds.