14.
K-Factor Settings
Note that the MMQ still must be one of the valid values listed above. If the MMQ is calculated
from the maximum flow, and is NOT one of the valid values listed above, it will be rounded up to
the next valid value. For example, if the maximum flow was 600:
  
30L is not a valid value, and therefore the MMQ would be rounded up to 50L.
The MMQ sets the display suppression. When a transaction starts, the quantity dispensed will
not show until a percentage of the MMQ has been dispensed. For LPG, display suppression is
4% of the MMQ. For non-LPG operation, display suppression is 2% of the MMQ. For example, if
the dispenser is in LPG mode and the MMQ is 2L:
 
So the quantity dispensed will not show until more than 0.08L has been dispensed.
Changing the V50 Meter ID
All V50 meters have a specific ID which must match the ID recorded in the dispenser settings.
This is a 6-digit number which can be found on the meter.
If the IDs do not match, the dispenser will return an error.
See Using the Dispenser Menus to edit these settings. Use the procedure for both side A and B.
As meter IDs are only relevant for V50 operation, this option will not show if the meter is not set
to V50.
id-A
802060